One solution would have been to stiffen the bridge to increase its natural frequencies and take these outside the excitation frequency range. However the artistic design of the bridge would have been compromised by stiffening and this was regarded as most undesirable. The alternative was to find a way of increasing the bridge’s inherently low damping so that self-excitation did not occur. It has been found that, below a threshold damping level, motion would build up, but that above the threshold damping level, self-excitation would not occur. Determining what this threshold level was and then providing a means of introducing the required amount of added damping proved a challenging task. It has involved adding 37 linear viscous dampers and over 50 tuned mass vibration absorbers to the initial structure. As a result, this bridge is now probably the most complex passively-damped structure in the world.

Figure 3 Centre span of the Millennium Bridge
Installing dampers in a way that was consistent with the aesthetic design of the bridge was difficult. A great deal of effort had been put into choosing a preferred design and the concept of “a blade of light” had been adopted and received widespread approval (see Deyan Sudjic (ed), Blade of Light: The Story of London’s Millennium Bridge, 2001). So far as possible dampers had to be mounted underneath the bridge deck so that they would be out-of-sight of everyone using the bridge.
(17) |
Although this has been arrived at by a completely different approach, it is identical with (16). This can
be verified by making the substitutions
,
,
,
, and
. Apart from different normalisation of the modal shape function, the
main difference is that Arup defined feedback force as proportional to velocity whereas the above analysis
begins by assuming that the feedback force is proportional to displacement (at a fixed frequency). Arup use
their symbol k not for stiffness but to relate pedestrian feedback force to deck lateral velocity,
whereas
as
defined above relates feedback force to deck lateral displacement.
Arup’s computation of their proportionality factor k was done by measuring the acceleration time history under conditions of steady-state crowd loading with a constant number of people walking steadily over each span (in turn) at the correct speed to resonate with the relevant mode. From this time-history, they calculated modal velocity (see Fitzpatrick et al, 2001, p. 14). If F is the amplitude of the modal feedback force (which is assumed proportional to velocity), D is the amplitude of the modal damping force (also proportional to velocity and known from previous measurements), and V is the amplitude of the modal velocity, then for conservation of energy,
(18) |
|||
| so that | |||
(19) |
|||
where m is modal mass, and A is the amplitude of the modal acceleration, since
. By plotting
calculated
from (19) (N is the number of people on the span) against modal velocity V, Arup arrived at an
average value for k. Some typical values are shown in figure 4 in which physical rather than modal
results are plotted. The approximately linear relationship in figure 4 appears to derive from the combined
action of two factors: the force per person increases (slowly) with amplitude and more people synchronise
with deck movement at larger amplitudes (see the additional material in Fitzpatrick et al, 2001). Linearity
is of course a starting assumption for the feedback model in part 1.

Figure 4. Correlation of pedestrian feedback force and deck velocity. The straight line shows average force exerted per pedestrian (Newtons) plotted against lateral deck velocity (m/s). (Arup figure, reproduced from Deyan Sudjic (ed), 2001, p. 93).
(18) |
The bridge deck is carried on lateral supports spaced periodically. These reach out to clamp onto the four parallel steel cables at each side of the deck. To a first approximation, the bridge vibrates like a taut string passing over supports at the two bridge piers and anchored to fixed supports at the river banks. Therefore lateral vibration involves shearing of the deck structure with no appreciable bending. All the low frequency modes have nodes at the attachment of the cables to the bridge piers and to the river bank anchorages. Although linear viscous dampers can be connected between the bridge deck and these fixed anchorages, the relative motion here is small and dampers fixed here cannot be made to work efficiently. Maximum relative shear displacement occurs between the lateral supports near anti-nodes, and therefore away from the fixed anchorages.
The solution adopted was to fit A-shaped frames to alternate lateral supports, with the points of two A’s meeting at the intermediate supports (as shown in figure 5).

Figure 5. Plan view of underside of deck showing installation of dampers(from Fitzpatrick et al. 2001)
Between the points of each pair of A frames, a linear viscous damper was mounted. It was possible to do this so that the moving parts were supported vertically on the upper-side of the lateral supports. All the viscous dampers were supplied by the US firm Taylor Devices, Inc. and incorporated metal bellows seals so that they are fully-sealed to the environment.
For the centre span, the damping introduced by frame-mounted viscous dampers was supplemented by the action of 4 pairs of laterally-acting tuned-mass vibration absorbers supplied by the German firm Gerb Schwingungsisolierungen GmbH, mounted
on the upper side of the bridge deck’s lateral supports, as shown in figure 5.
An additional 26 pairs of vertically-acting tuned-mass vibration absorbers were installed in similar positions on other lateral supports to increase vertical damping. This is to guard against the (unlikely) possibility that synchronous vertical vibration might occur when the lateral problem had been removed. The tuned-mass vibration absorbers have masses between 1 and 3 tonnes and they are located as close as possible to the antinodes of the modes that they are damping.
The performance targets for the modified bridge were expressed as rms acceleration levels measured at the quarter and half-span points with a 1 minute averaging time. The lateral target, after filtering with a passband of 0.2 to 2.4 Hz was that the rms should not exceed 25x10-3g laterally; the vertical target in a passband of 0.2 to 4.8 Hz was that the rms should not exceed 50x10-3g vertically. These targets were to be met in the presence of a test in which 2,000 people walked over the bridge three times at 0.6 m/s, 0.9 m/s and 1.2 m/s approximately with the bridge comfortably full of people. A great deal of planning went into the organisation and carrying out of this test which was successfully completed on 30 January 2002. Measured acceleration levels were substantially below the target limits for all the tests, typically less than one sixth of the agreed limits.

Figure 6. Onset of instability in crowd test on undamped north span, fundamental mode. As the number of people walking on the span (upper graph) increased to 166 progressively, the bridge lateral acceleration (lower graph)increased only slowly until instability was reached. The scale for acceleration is not given, but the peak acceleration reached was about 80x10-3 g at the right-hand side (Arup figure from Deyan Sudjic (ed), 2001, p. 93)